COMPLAINT CAUSE
REMEDY
USER QUALIFIED SERVICE AGENCY
*Water not hot enough Thermostat set too low. Set thermostat dial to a higher
temperature
Upper and/or lower temperature
probe out of calibration.
Call qualied service agency Check continuity and resistance (Ohms)
of upper and lower temperature probes.
Replace probes if out of specication.
*Insufcient hot water
*See WATER TEMPERATURE
CONTROL WARNING (on page
12).
Thermostat set too low. Set thermostat dial to a higher
temperature
Upper and/or lower temperature
probe out of calibration.
Call qualied service agency Check continuity and resistance (Ohms)
of upper and lower temperature probes.
Replace probes if out of specication.
Main manual gas shutoff valve
partially closed.
Open main manual gas shutoff
valve to fullest extent.
Heater too small for demand. Space usage to give heater time
to restore water temperature.
Heater recovery is slower. Call qualied service agency Check gas input. If incorrect, check
for inlet air blockage and/or ue gas
exhaust blockage.
Water temperature too hot. Thermostat set too high. Set thermostat to a lower setting.
Rumbling. Sediment accumulation on
bottom of tank.
Drain a quantity of water through
drain valve. If rumbling persists,
call a qualied service agency.
Delime heater.
Ticking or metallic sounds. Expansion and contraction -
normal.
Pounding or water hammer. Air chambers in piping have
become waterlogged. Thermal
expansion tank damaged,
improperly charged, or
improperly sized.
Drain piping system and rell.
Heater must be off while this
is being done. Check thermal
expansion tank charge pressure
when the water system pressure
is zero.
Follow the manufacturer's instructions
for proper charging of the thermal
expansion tank.
Water leaks. Drain valve not closed tightly. If drain valve cannot be closed
tightly, replace.
If leakage source cannot be
corrected or identied, call
qualied service agency.
Shut off gas supply to heater
and close cold water inlet valve
to heater.
Repair or in case of suspected tank
leakage, be certain to conrm before
replacing heater.
Gas odors. Possible gas leaks. Shut off gas supply to heater
and call gas company at once