SERVICING SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN
Service Handbook
COMMERCIAL GAS WATER HEATERS
FOR MODELS:
BCL3 95T199 6NOX, (A)BCL3 85T275 6NOX,
(A)BCL3 85T390 6NOX
ULTRA LOW NOx SERIES 100
INSTALLATION CONSIDERATIONS - PRE SERVICE CHECKS -
CONSTRUCTION - OPERATION & SERVICE - TROUBLESHOOTING
PO Box 1597, 500 Princeton Road
Johnson City, TN 37605
Page view 0
1 2 3 4 5 6 ... 37 38

Summary of Contents

Page 1 - COMMERCIAL GAS WATER HEATERS

PRINTED IN THE U.S.A. 0413 324660-001SERVICING SHOULD ONLY BE PERFORMED BY A QUALIFIED SERVICE TECHNICIANService HandbookCOMMERCIAL GAS WATER HEATERS

Page 2

8Servicing should only be performed by a Qualied Service TechnicianFEATURES AND COMPONENTS – ALL MODELSInlet TubeT & P Relief ValveUpper Thermost

Page 3 - TABLE OF CONTENTS

9Servicing should only be performed by a Qualied Service TechnicianBLOWER AND BURNER ASSEMBLYBURNER REPLACEMENT:1. Turn off the gas supply and elect

Page 4 - QUALIFICATIONS

10Servicing should only be performed by a Qualied Service Technician7. Remove the 4 brass nuts and 4 lock washers holding the flange plate to the sk

Page 5 - TOOLS REQUIRED

11Servicing should only be performed by a Qualied Service TechnicianSPARK IGNITER, FLAME SENSOR, SIGHT GLASSThe spark igniter and the flame sense rod

Page 6 - GAS PRESSURE – REQUIREMENTS

12Servicing should only be performed by a Qualied Service TechnicianVENTINGINSTALLATION – VENTING CATEGORY AND MATERIALSBCL3 MODELS VENTINGCategory I

Page 7 - AIR SUPPLY:

13Servicing should only be performed by a Qualied Service TechnicianEXTERIOR CLEARANCESThe illustration below shows the required clearances for venti

Page 8 - CONTAMINATED AIR:

14Servicing should only be performed by a Qualied Service TechnicianVENTING TABLES – TECHNICAL VENTING DATATYPE B GAS VENTMultiple Gas Fired Tank-Typ

Page 9 - POWER SUPPLY:

15Servicing should only be performed by a Qualied Service TechnicianTYPE B GAS VENTSingle Gas Fired Tank-Type HeaterWhen venting single tank type wat

Page 10

16Servicing should only be performed by a Qualied Service TechnicianOPERATION AND SERVICESEQUENCE OF OPERATION:1. Switch power on to unit.2. Thermo

Page 11 - BLOWER AND BURNER ASSEMBLY

17Servicing should only be performed by a Qualied Service TechnicianDIAGNOSTIC SEQUENCE OF OPERATION – FLOW CHART

Page 13

18Servicing should only be performed by a Qualied Service TechnicianSEQUENCE OF OPERATION – FLOW CHART

Page 14 - MINIMUM CLEARANCES

19Servicing should only be performed by a Qualied Service TechnicianLIGHTING AND OPERATING LABELSNOITCURTSNI GNITAREPOGNITAREPO EROFEB DAER YTEFAS RU

Page 15 - EXTERIOR CLEARANCES

20Servicing should only be performed by a Qualied Service TechnicianTROUBLESHOOTINGCOMPLAINT CAUSEREMEDYUSER QUALIFIED AGENCY*Water not hot enough. T

Page 16 - – TECHNICAL VENTING DATA

21Servicing should only be performed by a Qualied Service TechnicianCONTROLS OVERVIEW - CONTROL BOX ASSEMBLYVariable Frequency DriveDigital Thermosta

Page 17 - TYPE B GAS VENT

22Servicing should only be performed by a Qualied Service TechnicianPRESSURE SWITCHES – ALL MODELSAll models are provided with three pressure switche

Page 18 - OPERATION AND SERVICE

23Servicing should only be performed by a Qualied Service TechnicianBLOWER PROVER SWITCHThe blower prover switch is provided on the heater to verify

Page 19

24Servicing should only be performed by a Qualied Service TechnicianDISPLAY LIGHTS – DIGITAL THERMOSTATLED STATUSINDICATION ACTIONCalling for heat No

Page 20

25Servicing should only be performed by a Qualied Service TechnicianCONTINUITY CHECK OF HIGH LIMIT (ECO)Continuity check of ECO (energy cut-out, high

Page 21 - SNOITCURTSNI GNITAREPO

26Servicing should only be performed by a Qualied Service TechnicianUPPER TEMPERATURE PROBE CONTINUITY CHECKOHMS RESISTANCE TABLE° FOHMS70° 11,884120

Page 22 - TROUBLESHOOTING

27Servicing should only be performed by a Qualied Service TechnicianLOWER TEMPERATURE PROBE CONTINUITY CHECKOHMS RESISTANCE TABLE° FOHMS70° 11,884120

Page 23

1Servicing should only be performed by a Qualied Service TechnicianTABLE OF CONTENTSINTRODUCTION ...

Page 24 - BCL3 MODELS PRESSURE SWITCHES

28Servicing should only be performed by a Qualied Service TechnicianIGNITION CONTROLEach heater is equipped with an ignition control. The solid state

Page 25 - BLOCKED INLET SWITCH

29Servicing should only be performed by a Qualied Service TechnicianSTART UP/ FLAME RECOVERY/ SAFETY LOCKOUTSTART UP - HEAT MODEWhen a call for heat

Page 26 - INDICATION ACTION

30Servicing should only be performed by a Qualied Service TechnicianFAULT CONDITIONSThe water heater is equipped with an ignition control that incorp

Page 27 - CONDITIONS:

31Servicing should only be performed by a Qualied Service TechnicianVARIABLE FREQUENCY DRIVE – ALL MODELSThe BCL3 95T199 6NOX, (A)BCL3 85T275 6NOX an

Page 28 - OHMS RESISTANCE TABLE

32Servicing should only be performed by a Qualied Service TechnicianTwo conditions must be met for the variable frequency drive to switch the blower

Page 29

33Servicing should only be performed by a Qualied Service TechnicianWIRING DIAGRAM FOR (A)BCL3 95T1996NOX, 85T2756NOX AND 85T3906NOX WHEN EQUIPPED WI

Page 30 - IGNITION CONTROL

34Servicing should only be performed by a Qualied Service TechnicianNOTES

Page 31 - FAILURE TO LIGHT - LOCKOUT

35Servicing should only be performed by a Qualied Service TechnicianNOTES

Page 32 - FLAME SENSOR CURRENT CHECK

COMMERCIAL GAS WATER HEATERSVisit the "Information Central" link of www.americanwaterheater.com for a listing of available Service Handbooks

Page 33

2Servicing should only be performed by a Qualied Service TechnicianINTRODUCTIONThe service handbook is designed to aid in servicing and troubleshooti

Page 34 - Display:

3Servicing should only be performed by a Qualied Service TechnicianTOOLS REQUIRED• Electrical multimeter capable of measuring continuity/ ohms, ac &

Page 35 - WIRING DIAGRAM – ALL MODELS

4Servicing should only be performed by a Qualied Service TechnicianINSTALLATION CONSIDERATIONSGAS AND ELECTRICAL CHARACTERISTICSMODELS GAS TYPEGAS SU

Page 36

5Servicing should only be performed by a Qualied Service TechnicianAIR SUPPLY:Stoichiometric or theoretical complete combustion requires 10 cubic fee

Page 37

6Servicing should only be performed by a Qualied Service TechnicianMAKE-UP AIR – DIRECT COMMUNICATION WITH OUTDOORS:A fresh supply of make-up air for

Page 38

7Servicing should only be performed by a Qualied Service TechnicianAIR REQUIREMENTS:For safe operation an adequate supply of fresh uncontaminated air